Airchek touch,ปั๊มเก็บตัวอย่างอากาศ,SKC

SKC model : AirChek TOUCH

The new SKC AirChek TOUCH air sampling pump is the first personal sample pump with color touch screen navigation. The AirChek TOUCH air sampling pump provides extended flows from 5 to 5000 ml/min and high back pressure compensation for all of your IH applications.

  • Extended flows from 5 to 5000 ml/min
            – 5 to 500 ml/min with low flow adapter
            – Multi-tube sampling in low flow mode
  • Color touch screen navigation, easy programming
  • Continuous, timed, and intermittent sampling
  • Hands-free CalChek® calibration
  • High back pressure compensation
  • Powerful Li-Ion battery for long run times
  • Corrects flow for changes in temperature and atmospheric pressure
  • Screen protection and security
  • Ultra quiet
  • New DataTrac® Pro Software for easy pump and data management
           – Available for download; see Links tab
           – Hardware is required; see Related tab
Flow RangeConstant flow from 1000 to 5000 ml/min
(low flow from 5 to 500 ml/min requires adapter)
Compensation Range
(back pressure capability)
5000 ml/min at 20 inches water back pressure
4000 ml/min at 30 inches water back pressure
3000 ml/min at 40 inches water back pressure
2000 ml/min at 50 inches water back pressure
1000 ml/min at 50 inches water back pressure
Flow Control SystemPatented* isothermal, corrects for changes in back pressure, temperature, and atmospheric pressure
PowerRemovable rechargeable Lithium-ion (Li-Ion) battery, 7.4 V 2.6 Ah, 19.24 Wh or AC using charging cradle
Run Time20 hours at 2000 ml/min
10 hours at 5000 ml/min
Indefinite run from charging cradle
Charging Time
(varies with battery capacity and level of discharge)
Approximately 3 hours
AccuracyFlow control: ± 5% of set-point after calibration to desired flow
Atmospheric pressure: ± 0.3 in Hg
Temperature: ± 1.0 C
Temperature RangesOperating: 32 to 113 F (0 to 45 C)
Charging: 32 to 113 F (0 to 45 C)
Storage: -4 to 113 F (-20 to 45 C)
Humidity RangesOperating: < 95% RH, non-condensing
Storage: < 95% RH, non-condensing
AltitudeCorrects flow for chages in temperature (32 to 113 F/ 0 to 45 C) and ambient pressure up to 15,000 feet above and down to 4,500 feet below sea level
Display/parametersColor LCD/real-time flow rate, ambient temperature, ambient pressure, accumulated volume, elapsed time
User InterfaceResistive touch screen with auto-dim and locking options
Sound LevelAverage 51.7 dB at 3-ft (1-m) distance using a 37-mm 0.8-µm MCE filter cassette
Dimensions4.1 x 3.7 x 2.8 in (10.4 x 9.4 x 7.1 cm)
Weight19.4 oz (550 gm)
Certifications
  • Intrinsic safety: UL class I, Div. 1, Groups A, B, C, and D; Class II, Div 1, Groups E, F, and G; Class III, Div. 1, hazardous locations when used with SKC battery pack model P75718; T-code T3C. Exia; Class I, Zone 0 Gp IIC (SKC Cat. No. 220-5000TC)
  • RoHS compliant
  • CE Marked
Case MaterialPolycarbonate with rubberized anti-static overmolding